Current Delivery Schedule – We Are Open & Processing Orders - Please Click Here For the Latest Delivery Information.
search
Continuous Roll out Rafter Tray 400mm x 6m Harcon RT66
Code: RT66
£ 4.71
(Inc £5.65)
Corovent 400mm x 6m Rafter Tray Provides 25mm per LM Air Gap to fit common rafter spacings. The continuous roll out rafter tray incorporates structural profiling which dramatically improves rigidity.
Continuous Roll Out Rafter Tray 400mm x 6m

The Harcon Corovent continuous rafter tray has recently been redesigned in line with roofers’ requests. Typical roll formed rafter trays easily flatten and stretch, reducing the ventilation path. The Harcon continuous rafter tray uniquely solves this problem by incorporating structural profiling which dramatically improves rigidity, so a full 25mm air path is guaranteed down the line of the roof.

As insulation becomes ever thicker, it is increasingly difficult to maintain a clear path to the eaves and locate the tray in the right place. Roof insulation can either slide below the tray and block ventilation, or push against the upper end causing blockage. Use of narrow rafter trays which do not prevent this should be avoided.

Features:
  • Width 400mm - Significantly wider than most roll formed rafter trays
  • 6m length - fast to install
  • Structurally profiled
  • Better rigidty than standard continuos rafter trays
  • Maintains a full 25mm air path down the line of the roof
  • 400mm deep
  • Will cover a 200mm depth of insulation at a minimum 30 degree pitch
  • Continuous Rafter Tray Data Sheet RT66
Manufacturer: Harcon Corovent
Product Code: RT66

►Return to product list
DELIVERY INFORMATION

We offer a free standard delivery service on all orders over £500.00*. Orders under £500.00* will be charged £15.00* carriage.
Our standard delivery area covers mainland England, Scotland (Excluding Highlands) and Wales. For all other areas around the UK an additional delivery charge will need to be applied, we will advise you of this charge before your order is dispatched. For deliveries to these areas we are happy to provide a free quotation upon request.
Please note: Roof Vents are not available for delivery to Ireland and Northern Ireland.

DELIVERY DATES AND TIMES

Please click here or see COVID-19 banner at the top of the page for the latest delivery shedule.

We will always do our best to deliver stocked items ordered via our website within 3-5 working days. This applies to  goods ordered before 12.00pm and in stock.
Some of our products, because of their size (5m and over) and weight (over 80 kilos), have an estimated 3 to 5 working day lead time but we will endeavour to get them to you as soon as possible.
All the Roof Vent Products are made to order and have an estimated 7-10 working day lead time. This can be reduced for sites wishing to call off quantities that have been given to us in advance (call for further information). Please note: All Roof Vents are made to order and non returnable.
Please note: Roof Vents are not available for delivery to Ireland and Northern Ireland.
The Mardome Hi-Lights Range of Dome Rooflights have a 48 hour delivery schedule. Orders must be received by 1pm to qualify for the 48 hour (2 working days) delivery. Only available to mainland GB (excluding postcode areas begining KW, IV, AB, and PH)
CORRAPOL-BT Bitumen Roofing Sheets 1-2 working days.
We regret that timed deliveries cannot be given. Deliveries will be made between 8.00am and 5.30pm Monday to Friday.

SIGNING FOR YOUR DELIVERY

All deliveries should be signed for and we would politely request that you sign and clearly print your name so that in the unlikely event that there are any discrepancies we will have a person to contact. If a signature cannot be obtained we will try to leave the goods in a safe location, but we cannot be held responsible for shortages or damages where goods have not been signed for.

ACCEPTING YOUR GOODS

Large or palletised goods will be delivered to a hard standing area only. The Customer shall be solely responsible for the unloading of the Goods and the Seller shall not be liable for any damage that occurs in the course of such unloading.
Any shortages must be reported within 48 hours.

DELIVERY VEHICLE
 
If goods aren't sent by our own vehicles they are sent by reputable carriers such as Tufnell's, Fed-Ex  and Parcel Force. Heavier goods may be delivered by larger vehicles and will be off loaded as close as possible to the property whilst remaining on a hard standing surface.

GOOD ADVICE

Please do not arrange any labour until your materials are on site as we are unable to compensate you for your time in the event of a late delivery.
 
If you have ANY questions about our products, or want to give us some feedback about your shopping experience with us, please feel free to contact us on 03302 230 267 or email: customerservices
 
*excluding VAT
Eaves Comb Filler Installation Details

The base of the comb is marked with positions for nailingeither directly onto the fascia board or on top a Harcon Over Fascia Roof Vent if fitted.



Eaves Fascia Tray Installation Details

Position the tray on top of the fascia board and nail in place. Adjacent trays are designed to lap over each other easily forming a continuous run.

The Harcon facia tray should sit on top of the Harcon over fascia roof vent if fitted and the two may be fixed in place simultaneously. Harcon comb fillersmay also be fixed in place at the same time.


Soffit Disc Vent Installation

  1. The first thing you need to do is find your rafters. That done, mark the points halfway between them. These will be the locations of your soffit vents. Mark them with a pencil.
  2. Take your drill and find the proper bits for the particular vents. The hole saw should be smaller than the flanges of the vent, but still big enough to install the vent. Drill the holes on the marks you made earlier.
  3. Now that you have the holes, push the round vents into them. You can use silicone, if you want, to make sure the flanges are holding properly. You can also use the silicone to fill any gaps. Now, screw the vents into the soffit.
Continuous Roll Out Rafter Tray 400mm x 6m

The Harcon Corovent continuous rafter tray has recently been redesigned in line with roofers’ requests. Typical roll formed rafter trays easily flatten and stretch, reducing the ventilation path. The Harcon continuous rafter tray uniquely solves this problem by incorporating structural profiling which dramatically improves rigidity, so a full 25mm air path is guaranteed down the line of the roof.

As insulation becomes ever thicker, it is increasingly difficult to maintain a clear path to the eaves and locate the tray in the right place. Roof insulation can either slide below the tray and block ventilation, or push against the upper end causing blockage. Use of narrow rafter trays which do not prevent this should be avoided.

Features:
  • Width 400mm - Significantly wider than most roll formed rafter trays
  • 6m length - fast to install
  • Structurally profiled
  • Better rigidty than standard continuos rafter trays
  • Maintains a full 25mm air path down the line of the roof
  • 400mm deep
  • Will cover a 200mm depth of insulation at a minimum 30 degree pitch
  • Continuous Rafter Tray Data Sheet RT66
Manufacturer: Harcon Corovent
Product Code: RT66

►Return to product list
DELIVERY INFORMATION

We offer a free standard delivery service on all orders over £500.00*. Orders under £500.00* will be charged £15.00* carriage.
Our standard delivery area covers mainland England, Scotland (Excluding Highlands) and Wales. For all other areas around the UK an additional delivery charge will need to be applied, we will advise you of this charge before your order is dispatched. For deliveries to these areas we are happy to provide a free quotation upon request.
Please note: Roof Vents are not available for delivery to Ireland and Northern Ireland.

DELIVERY DATES AND TIMES

Please click here or see COVID-19 banner at the top of the page for the latest delivery shedule.

We will always do our best to deliver stocked items ordered via our website within 3-5 working days. This applies to  goods ordered before 12.00pm and in stock.
Some of our products, because of their size (5m and over) and weight (over 80 kilos), have an estimated 3 to 5 working day lead time but we will endeavour to get them to you as soon as possible.
All the Roof Vent Products are made to order and have an estimated 7-10 working day lead time. This can be reduced for sites wishing to call off quantities that have been given to us in advance (call for further information). Please note: All Roof Vents are made to order and non returnable.
Please note: Roof Vents are not available for delivery to Ireland and Northern Ireland.
The Mardome Hi-Lights Range of Dome Rooflights have a 48 hour delivery schedule. Orders must be received by 1pm to qualify for the 48 hour (2 working days) delivery. Only available to mainland GB (excluding postcode areas begining KW, IV, AB, and PH)
CORRAPOL-BT Bitumen Roofing Sheets 1-2 working days.
We regret that timed deliveries cannot be given. Deliveries will be made between 8.00am and 5.30pm Monday to Friday.

SIGNING FOR YOUR DELIVERY

All deliveries should be signed for and we would politely request that you sign and clearly print your name so that in the unlikely event that there are any discrepancies we will have a person to contact. If a signature cannot be obtained we will try to leave the goods in a safe location, but we cannot be held responsible for shortages or damages where goods have not been signed for.

ACCEPTING YOUR GOODS

Large or palletised goods will be delivered to a hard standing area only. The Customer shall be solely responsible for the unloading of the Goods and the Seller shall not be liable for any damage that occurs in the course of such unloading.
Any shortages must be reported within 48 hours.

DELIVERY VEHICLE
 
If goods aren't sent by our own vehicles they are sent by reputable carriers such as Tufnell's, Fed-Ex  and Parcel Force. Heavier goods may be delivered by larger vehicles and will be off loaded as close as possible to the property whilst remaining on a hard standing surface.

GOOD ADVICE

Please do not arrange any labour until your materials are on site as we are unable to compensate you for your time in the event of a late delivery.
 
If you have ANY questions about our products, or want to give us some feedback about your shopping experience with us, please feel free to contact us on 03302 230 267 or email: customerservices
 
*excluding VAT
Eaves Comb Filler Installation Details

The base of the comb is marked with positions for nailingeither directly onto the fascia board or on top a Harcon Over Fascia Roof Vent if fitted.



Eaves Fascia Tray Installation Details

Position the tray on top of the fascia board and nail in place. Adjacent trays are designed to lap over each other easily forming a continuous run.

The Harcon facia tray should sit on top of the Harcon over fascia roof vent if fitted and the two may be fixed in place simultaneously. Harcon comb fillersmay also be fixed in place at the same time.


Soffit Disc Vent Installation

  1. The first thing you need to do is find your rafters. That done, mark the points halfway between them. These will be the locations of your soffit vents. Mark them with a pencil.
  2. Take your drill and find the proper bits for the particular vents. The hole saw should be smaller than the flanges of the vent, but still big enough to install the vent. Drill the holes on the marks you made earlier.
  3. Now that you have the holes, push the round vents into them. You can use silicone, if you want, to make sure the flanges are holding properly. You can also use the silicone to fill any gaps. Now, screw the vents into the soffit.
Customer Reviews (0)