Contact Us
Item Code: URS6/B,Dry Fix Ridge

Universal Dry Ridge System x 6m Harcon URS6/B

£58.27
( Incl VAT £69.92)
Corovent Universal Vented Dry Ridge System - 6m Rollout Tray, Union Kit and Metal Clamps, Ridge Brackets URS6/B
Est. Delivery 2 - 3 Working Days
Order in the next Hours Mins and Seconds,
To get your item delivered on Tuesday

Dry Fix Ridge


The Universal Dry Fix Ridge System consists of 6m x 300mm Dry Ridge Roll Out Tray, 13 x Dry Ridge Union Strips, fixings caps and screw, 13 x Dry Ridge Caps and 13 x Dry Ridge Brackets.

Features:
  • Universal ridge fixing system
  • Unique jointing system for ultimate versatility
  • Accommodates most known ridge tiles
  • Can be used with both half round and angled ridges
  • Dry fix is the fastest way to install ridge tiles
  • No wet trades needed
  • Smooth line providing a discreet appearance
  • Union strip and cap are available in Black or Mortar Grey
Manufacturer: Harcon Corovent
Product Code: URS6/B

►Return to product list

Delivery Information


Delivery Charges

We offer a free standard delivery service on all orders over £500.00*. Orders under £500.00* will be charged a delivery fee. All delivery charges are calculated at basket and are dependent on the items ordered.

Our standard delivery area covers mainland England, Scotland (Excluding Highlands) and Wales. For all other areas around the UK an additional delivery charge will need to be applied, we will advise you of this charge before your order is dispatched. For deliveries to these areas we are happy to provide a free quotation upon request.

Free Delivery Exclusions

  • All Tapco Products
  • Roof Vents are not available for delivery to Ireland and Northern Ireland.

Mardome Rooflights

It is important to note that all Mardome rooflight orders are subject to a failed delivery charge in the event of unsuccessful delivery. This fee is £85 ex VAT and must be taken into account when making your purchase.

If you wish to return your order, please contact us. However, it is important to note that due to many Mardome rooflights being made to order, returns are only accepted in exceptional circumstances and a collection charge of £85 ex VAT will be applied if approved. We recommend taking the time to review your order carefully before making payment as this fee is non-refundable.

Should you have any queries regarding Mardome rooflights, please don't hesitate to contact us. Our team are dedicated to providing excellent customer service and will be more than happy to answer any questions you may have.


Delivery Dates and Times

We will always do our best to deliver stocked items ordered via our website within 3-5 working days. This applies to goods ordered before 12.00pm and in stock.

Please see estimated delivery times (Est. Delivery) on each product.


Roof Tile Vents

All the Roof Tile Vents and Cowls are made to order (due to thousands of combinations of different variants available) bespoke items which are non-returnable.
 


Other Information

Some of our products, because of their size (5m and over) and weight (over 80 kilos), have an estimated 5 to 7 working day lead time but we will endeavour to get them to you as soon as possible.

Maximum number of roof sheets available on one delivery is 40, otherwise a forklift is required please call for more information.

The Mardome Hi-Lights Range of Dome Rooflights have a 48 hour delivery schedule. Orders must be received by 1pm to qualify for the 48 hour (2 working days) delivery. Only available to mainland GB (excluding postcode areas begining KW, IV, AB, and PH).

We regret that timed deliveries cannot be given. Deliveries will be made between 8.00am and 5.30pm Monday to Friday.


Made to Order Item's (Bespoke Items)

Please note all made to order items are made are non-returnable.

Signing For Your Delivery

All deliveries should be signed for and we would politely request that you sign and clearly print your name so that in the unlikely event that there are any discrepancies we will have a person to contact. If a signature cannot be obtained we will try to leave the goods in a safe location, but we cannot be held responsible for shortages or damages where goods have not been signed for.

Accepting Your Goods

Large or palletised goods will be delivered to a hard standing area only. The Customer shall be solely responsible for the unloading of the Goods and the Seller shall not be liable for any damage that occurs in the course of such unloading.

Any shortages or damages must be reported within 48 hours.

Delivery Vehicle

If goods aren't sent by our own vehicles they are sent by reputable carriers such as Tufnell's, Fed-Ex and Parcel Force. Heavier goods may be delivered by larger vehicles and will be off loaded as close as possible to the property whilst remaining on a hard standing surface.

Good Advice

Please do not arrange any labour until your materials are on site as we are unable to compensate you for your time in the event of a late delivery.

If you have ANY questions about our products, or want to give us some feedback about your shopping experience with us, please feel free to contact us on 03302 230 267 or email: [email protected]

*excluding VAT

Corovent URS Universal Dry Ridge System Installation Guide

1.
Fix one bracket at each rafter. Bend lower legs of bracket to chosen ridge tiles, allowing stainless steel fixing screw (see stage 6) to penetrate ridge batten at a minimum of 20mm.

Correct bending position is best found by temporarily placing top tile batten and a few roof and ridge tiles and eyeing up bracket position beneath ridge tile. Subsequent brackets should be bent identically to the first.

2a. Push ridge batten (minimum 25mm x 50mm) firmly onto location spikes.
CAUTION: DO NOT USE A HAMMER - PUSH BATTEN ONLY.

2b. When ridge batten is in place, bend bracket upper legs over and fix through holes with nails provided.
CAUTION: TAKE CARE NOT TO FURTHER BEND BRACKET LOWER LEGS WHEN FIXING.
Proceed to lay top row of tiles.

3. Unroll ridge-roll and fix with a nail at 1-2m centres. Ridge roll should overlap at edge of gable end by approx. 50mm when using a dry verge or block end ridge tile. When using a bedded verge, stop ridge roll 50mm short from edge of gable end.
Peel backing from mastic strips and press firmly onto tile, checking for good adhesion. Do not attempt fixing if tile is wet or temperature is below 5 degrees C.
If ridge is longer than 6m, overlap rolls by a minimum of 75mm and place a nail in the centre of the lap.

4. Assemble cap to union and push onto ridge tile.
Cap and union assembly should grip ridge tile without deformation to cap.
Only if needed i.e. triangular ridge tiles, cap arms can be bent at bend point indicated.
CAUTION: BEND ONLY ONCE. REPEATED BENDING CAN OVERSTRESS THE COMPONENT AND LEAD TO PREMATURE FAILURE.

5. Push next ridge tile firmly into place, trapping it between the cap and the union. Ridge tiles at end of ridge must be full tiles, do not cut down.

6. Fix through hole in centre of cap using 75mm stainless steel screws provided.
CAUTION: DO NOT USE NAILS.
Screw should be tightened so that ridge tiles do not lift.
Cap should not deform more than 3mm from its original shape.

NOTE: If at this point it is discovered that the brackets were not set high enough at stage 1. another batten can be screw fixed on top of the original to achieve correct engagement. Ensure additional batten does not block vent holes in ridge roll.
7. Click side arms into place.
Data Sheets for the Dry Ridge System

Corovent Universal Ridge System (URS) Leaflet

Corovent Dry Fix Ridge Data Sheet

Guidance

Simple Installation
  1. Fix one bracket at each rafter. Bend lower legs of bracket to suit chosen ridge tile, allowing stainless steel fixing screw (see stage 7) to penetrate ridge batten at a minimum of 20mm. Correct bending position is best found by temporarily placing top tile batten and a few roof and ridge tiles and eyeing up bracket position beneath ridge tile. Subsequent brackets should be bent identically to the first.
  2. Push ridge batten (min 25mm x 50mm) firmly onto location spikes. Caution: Do not use a hammer - push batten only!
  3. When ridge batten is in place, bend bracket upper legs over and fix through holes with nails provided. Caution: Take care not to further bend bracket lower legs when fixing! Proceed to lay top row of roof tiles.
  4. Unroll ridge-roll and fix with nail at 1-2m centres. Peel backing from mastic strips and press firmly onto tile, checking for good adhesion. Do not attempt fixing if tile is wet or temperature is below 5°c. If ridge is longer than 6m, overlap rolls by a minimum of 75mm and place a nail in the of the lap.
  5. Pre-bend union to match ridge tile. Assemble cap to union and push onto ridge tile. Cap & Union assembly should grip ridge tile without deformation to cap. Only if needed i.e. triangular ridge tiles, cap arms can be bent at bend point indicated. Caution: Bend once only. Repeated bending can overstress the component and lead to premature failure!
  6. Push next ridge tile firmly into place, trapping it between the cap and the union.
  7. Fix through hole in centre of cap using 75mm stainless steel screws provided. Caution: Do not use nails! Screw should be tightened so that ridge tiles do not lift. Cap should not deform more than 3mm from its original shape. Note: If at this point it is discovered that the brackets were not set high enough at stage 1, another batten can be screw fixed on top of the original to achieve correct engagement. Ensure additional batten does not block vent holes in ridge roll.
  8. Click side arms into place. Ridge roll should overlap at edge of gable end by approx. 50mm when using a dry verge or black end ridge tile. When using a bedded verge, stop ridge roll 50mm short from edge of gable end. Ridge tiles at end of ridge must be full tiles, do not cut down.

Dry Fix Ridge


The Universal Dry Fix Ridge System consists of 6m x 300mm Dry Ridge Roll Out Tray, 13 x Dry Ridge Union Strips, fixings caps and screw, 13 x Dry Ridge Caps and 13 x Dry Ridge Brackets.

Features:
  • Universal ridge fixing system
  • Unique jointing system for ultimate versatility
  • Accommodates most known ridge tiles
  • Can be used with both half round and angled ridges
  • Dry fix is the fastest way to install ridge tiles
  • No wet trades needed
  • Smooth line providing a discreet appearance
  • Union strip and cap are available in Black or Mortar Grey
Manufacturer: Harcon Corovent
Product Code: URS6/B

►Return to product list

Delivery Information


Delivery Charges

We offer a free standard delivery service on all orders over £500.00*. Orders under £500.00* will be charged a delivery fee. All delivery charges are calculated at basket and are dependent on the items ordered.

Our standard delivery area covers mainland England, Scotland (Excluding Highlands) and Wales. For all other areas around the UK an additional delivery charge will need to be applied, we will advise you of this charge before your order is dispatched. For deliveries to these areas we are happy to provide a free quotation upon request.

Free Delivery Exclusions

  • All Tapco Products
  • Roof Vents are not available for delivery to Ireland and Northern Ireland.

Mardome Rooflights

It is important to note that all Mardome rooflight orders are subject to a failed delivery charge in the event of unsuccessful delivery. This fee is £85 ex VAT and must be taken into account when making your purchase.

If you wish to return your order, please contact us. However, it is important to note that due to many Mardome rooflights being made to order, returns are only accepted in exceptional circumstances and a collection charge of £85 ex VAT will be applied if approved. We recommend taking the time to review your order carefully before making payment as this fee is non-refundable.

Should you have any queries regarding Mardome rooflights, please don't hesitate to contact us. Our team are dedicated to providing excellent customer service and will be more than happy to answer any questions you may have.


Delivery Dates and Times

We will always do our best to deliver stocked items ordered via our website within 3-5 working days. This applies to goods ordered before 12.00pm and in stock.

Please see estimated delivery times (Est. Delivery) on each product.


Roof Tile Vents

All the Roof Tile Vents and Cowls are made to order (due to thousands of combinations of different variants available) bespoke items which are non-returnable.
 


Other Information

Some of our products, because of their size (5m and over) and weight (over 80 kilos), have an estimated 5 to 7 working day lead time but we will endeavour to get them to you as soon as possible.

Maximum number of roof sheets available on one delivery is 40, otherwise a forklift is required please call for more information.

The Mardome Hi-Lights Range of Dome Rooflights have a 48 hour delivery schedule. Orders must be received by 1pm to qualify for the 48 hour (2 working days) delivery. Only available to mainland GB (excluding postcode areas begining KW, IV, AB, and PH).

We regret that timed deliveries cannot be given. Deliveries will be made between 8.00am and 5.30pm Monday to Friday.


Made to Order Item's (Bespoke Items)

Please note all made to order items are made are non-returnable.

Signing For Your Delivery

All deliveries should be signed for and we would politely request that you sign and clearly print your name so that in the unlikely event that there are any discrepancies we will have a person to contact. If a signature cannot be obtained we will try to leave the goods in a safe location, but we cannot be held responsible for shortages or damages where goods have not been signed for.

Accepting Your Goods

Large or palletised goods will be delivered to a hard standing area only. The Customer shall be solely responsible for the unloading of the Goods and the Seller shall not be liable for any damage that occurs in the course of such unloading.

Any shortages or damages must be reported within 48 hours.

Delivery Vehicle

If goods aren't sent by our own vehicles they are sent by reputable carriers such as Tufnell's, Fed-Ex and Parcel Force. Heavier goods may be delivered by larger vehicles and will be off loaded as close as possible to the property whilst remaining on a hard standing surface.

Good Advice

Please do not arrange any labour until your materials are on site as we are unable to compensate you for your time in the event of a late delivery.

If you have ANY questions about our products, or want to give us some feedback about your shopping experience with us, please feel free to contact us on 03302 230 267 or email: [email protected]

*excluding VAT

Corovent URS Universal Dry Ridge System Installation Guide

1.
Fix one bracket at each rafter. Bend lower legs of bracket to chosen ridge tiles, allowing stainless steel fixing screw (see stage 6) to penetrate ridge batten at a minimum of 20mm.

Correct bending position is best found by temporarily placing top tile batten and a few roof and ridge tiles and eyeing up bracket position beneath ridge tile. Subsequent brackets should be bent identically to the first.

2a. Push ridge batten (minimum 25mm x 50mm) firmly onto location spikes.
CAUTION: DO NOT USE A HAMMER - PUSH BATTEN ONLY.

2b. When ridge batten is in place, bend bracket upper legs over and fix through holes with nails provided.
CAUTION: TAKE CARE NOT TO FURTHER BEND BRACKET LOWER LEGS WHEN FIXING.
Proceed to lay top row of tiles.

3. Unroll ridge-roll and fix with a nail at 1-2m centres. Ridge roll should overlap at edge of gable end by approx. 50mm when using a dry verge or block end ridge tile. When using a bedded verge, stop ridge roll 50mm short from edge of gable end.
Peel backing from mastic strips and press firmly onto tile, checking for good adhesion. Do not attempt fixing if tile is wet or temperature is below 5 degrees C.
If ridge is longer than 6m, overlap rolls by a minimum of 75mm and place a nail in the centre of the lap.

4. Assemble cap to union and push onto ridge tile.
Cap and union assembly should grip ridge tile without deformation to cap.
Only if needed i.e. triangular ridge tiles, cap arms can be bent at bend point indicated.
CAUTION: BEND ONLY ONCE. REPEATED BENDING CAN OVERSTRESS THE COMPONENT AND LEAD TO PREMATURE FAILURE.

5. Push next ridge tile firmly into place, trapping it between the cap and the union. Ridge tiles at end of ridge must be full tiles, do not cut down.

6. Fix through hole in centre of cap using 75mm stainless steel screws provided.
CAUTION: DO NOT USE NAILS.
Screw should be tightened so that ridge tiles do not lift.
Cap should not deform more than 3mm from its original shape.

NOTE: If at this point it is discovered that the brackets were not set high enough at stage 1. another batten can be screw fixed on top of the original to achieve correct engagement. Ensure additional batten does not block vent holes in ridge roll.
7. Click side arms into place.
Data Sheets for the Dry Ridge System

Corovent Universal Ridge System (URS) Leaflet

Corovent Dry Fix Ridge Data Sheet

Guidance

Simple Installation
  1. Fix one bracket at each rafter. Bend lower legs of bracket to suit chosen ridge tile, allowing stainless steel fixing screw (see stage 7) to penetrate ridge batten at a minimum of 20mm. Correct bending position is best found by temporarily placing top tile batten and a few roof and ridge tiles and eyeing up bracket position beneath ridge tile. Subsequent brackets should be bent identically to the first.
  2. Push ridge batten (min 25mm x 50mm) firmly onto location spikes. Caution: Do not use a hammer - push batten only!
  3. When ridge batten is in place, bend bracket upper legs over and fix through holes with nails provided. Caution: Take care not to further bend bracket lower legs when fixing! Proceed to lay top row of roof tiles.
  4. Unroll ridge-roll and fix with nail at 1-2m centres. Peel backing from mastic strips and press firmly onto tile, checking for good adhesion. Do not attempt fixing if tile is wet or temperature is below 5°c. If ridge is longer than 6m, overlap rolls by a minimum of 75mm and place a nail in the of the lap.
  5. Pre-bend union to match ridge tile. Assemble cap to union and push onto ridge tile. Cap & Union assembly should grip ridge tile without deformation to cap. Only if needed i.e. triangular ridge tiles, cap arms can be bent at bend point indicated. Caution: Bend once only. Repeated bending can overstress the component and lead to premature failure!
  6. Push next ridge tile firmly into place, trapping it between the cap and the union.
  7. Fix through hole in centre of cap using 75mm stainless steel screws provided. Caution: Do not use nails! Screw should be tightened so that ridge tiles do not lift. Cap should not deform more than 3mm from its original shape. Note: If at this point it is discovered that the brackets were not set high enough at stage 1, another batten can be screw fixed on top of the original to achieve correct engagement. Ensure additional batten does not block vent holes in ridge roll.
  8. Click side arms into place. Ridge roll should overlap at edge of gable end by approx. 50mm when using a dry verge or black end ridge tile. When using a bedded verge, stop ridge roll 50mm short from edge of gable end. Ridge tiles at end of ridge must be full tiles, do not cut down.
Customer Reviews (0)